Accreditations
- AAMA 501.1 Test Method for Water Penetration of Windows, Curtain Walls, and Doors Using Dynamic Pressure
- AAMA 501.2 Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems
- AAMA 501.4 Testing Method for Evaluating Curtain Wall and Storefront Systems Subjected to Seismic and Wind Induced Interstory Drift
- AAMA 501.5 Test Method for Thermal Cycling of Exterior Walls
- AAMA 501.7 Test Method for Evaluating Windows, Window Wall, Curtain Wall and Storefront Systems Subjected to Vertical Interstory Movement
- AAMA 501.8 Test Method for Determination of Resistance to Human Impact of Window Systems Intended for Use in Psychiatric Applications
- AAMA 502 Voluntary Specification for Field Testing of Newly Installed Fenestration Products
- AAMA 503 Voluntary Specification for Field Testing of Newly Installed Storefronts, Curtain Walls and Sloped Glazing Systems
- AAMA 513 Test Method for Determining Forces and Motions Required to Activate Operable Parts of CW and AW Class Operable Windows, Sliding Glass Doors and Terrace Doors in Accessible Spaces
- AAMA 910 Voluntary Life Cycle Spec and Test Methods for Architectural Grade Windows and Sliding Glass Doors
- AAMA 920 Specification for Operating Cycle Performance of Active Side-Hinged Exterior Door Slabs
- AAMA 925 Specification for Determining the Vertical Load Resistance of Side Hinged Doors
- AAMA 930 Voluntary Specification for Water Penetration Resistance and Structural Load Performance of Locking/Latching Hardware
- AAMA 1304 Voluntary Specification for Force Entry of Side Hinged Door Systems
- AAMA 1503 Voluntary Test Method for Thermal Transmittance and CR of Windows, Doors and Glazed Wall
- ANSI Z97.1 Specification for Safety Glazing Materials Used in Buildings
- ASTM E283 Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen
- ASTM E330 Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference
- ASTM E331 Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference
- ASTM E547 Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference
- ASTM E783 Test Method for Field Measurement of Air Leakage Through Installed Exterior Windows and Doors
- ASTM E987 Test Methods for Deglazing Force of Fenestration Products
- ASTM E1105 Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform of Cyclic Static Air Pressure Difference
- ASTM E1233 Test Method for Structural Performance of Exterior Windows, Doors, Skylights, and Curtain Walls by Cyclic Air Pressure Differential
- ASTM E1886 Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials
- ASTM E2068 Test Method for Determination of Operating Force of Sliding Windows and Doors
- ASTM F588 Test Methods for Measuring the Forced Entry Resistance of Window Assemblies, Excluding Glazing Impact
- ASTM F842 Test Methods for Measuring the Forced Entry Resistance of Sliding Door Assemblies, Excluding Glazing Impact
- AAMA 450 Voluntary Performance Rating Method for Mulled Fenestration Assemblies
- AAMA 501.1 Test Method for Water Penetration of Windows, Curtain Walls, and Doors Using Dynamic Pressure
- AAMA 501.2 Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems
- AAMA 501.4 Testing Method for Evaluating Curtain Wall and Storefront Systems Subjected to Seismic and Wind Induced Interstory Drift
- AAMA 501.5 Test Method for Thermal Cycling of Exterior Walls
- AAMA 501.7 Test Method for Evaluating Windows, Window Wall, Curtain Wall and Storefront Systems Subjected to Vertical Interstory Movement
- AAMA 502 Voluntary Specification for Field Testing of Newly Installed Fenestration Products
- AAMA 503 Voluntary Specification for Field Testing of Newly Installed Storefronts, Curtain Walls and Sloped Glazing Systems
- AAMA 513 Test Method for Determining Forces and Motions Required to Activate Operable Parts of CW and AW Class Operable Windows, Sliding Glass Doors and Terrace Doors in Accessible Spaces
- AAMA 520 Voluntary Specification for Rating the Severe Wind-Driven Rain Resistance of Windows, Doors, and Unit Skylights
- AAMA 910 Voluntary Life Cycle Specification and Test Methods for Architectural Grade Windows and Sliding Glass Doors
- AAMA 1304 Voluntary Specification for Force Entry of Side Hinged Door Systems
- AAMA 1503 Voluntary Test Method for Thermal Transmittance and Condensation Resistance of Windows, Doors and Glazed Wall Sections
- AAMA 1701.2 Voluntary Standard for Utilization in Manufactured Housing for Primary Windows and Sliding Glass Doors
- AAMA 1702.2 Voluntary Standard for Utilization in Manufactured Housing for Swinging Exterior Passage Doors
- AAMA 1704 Voluntary Standard Egress Window Systems for Utilization in Manufactured Housing
- AAMA/WDMA/CSA 101/I.S.2/A440 North American Fenestration Standard/Specification for Windows, Doors, and Skylights
- AMCA 540 Test Method for Louvers Impacted by Wind Borne Debris
- AMCA 550 Test Method for High Velocity Wind Driven Rain Resistant Louvers
- ANSI/DASMA108 Standard Method for Testing Sectional Garage Doors and Rolling Doors: Determination of Structural Performance Under Uniform Static Air Pressure Difference
- ANSI/DASMA115 Standard Method for Testing Sectional Doors, Rolling Doors, and Flexible Doors: Determination of Structural Performance Under Missile Impact and Cyclic Wind Pressure
- ASTM C1060 Thermographic Inspection of Insulation Installations in Envelope Cavities of Frame Buildings
- ASTM C1199 Standard Test Method for Measuring the Steady State Thermal Transmittance of Fenestration Systems Using Hot Box Methods
- ASTM C1363 Standard Test Method for Thermal Performance of Building Material and Envelope Assemblies by Means of Hot Box Apparatus
- ASTM C1521 Standard Practice for Evaluating Adhesion of Installed Weatherproofing Sealant Joints
- ASTM D 4541 Standard Test Method for Pull-Off Strength of Coatings Using Portable Adhesion Testers
- ASTM D7877 Electronic Methods for Detecting and Locating Leaks in Waterproof Membranes
- ASTM D8231 Use of Low Voltage Electronic Scanning System for Detecting and Locating Breaches in Roofing and Waterproofing Membranes
- ASTM E72 Standard Test Methods of Conduction Strength Tests of Panels for Building Construction
- ASTM E283 Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen
- ASTM E330 Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference
- ASTM E331 Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference
- ASTM E547 Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference
- ASTM E661 Test Method for Performance of Wood and Wood-Based Floor and Roof Sheathing Under Concentrated Static and Impact Loads
- ASTM E 779 Standard Test Method for Determining Air Leakage Rate by Fan Pressurization
- ASTM E783 Test Method for Field Measurement of Air Leakage Through Installed Exterior Windows and Doors
- ASTM E907 Test Method for Field Testing Uplift Resistance of Adhered Membrane Roofing Systems
- ASTM E935 Test Methods for Performance of Permanent Metal Railing Systems and Rails for Buildings
- ASTM E987 Test Methods for Deglazing Force of Fenestration Products
- ASTM E1105 Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform of Cyclic Static Air Pressure Difference
- ASTM E1186 Standard Practices for Air Leakage Site Detection in Building Envelopes and Air Barrier Systems
- ASTM E1423 Standard Practice for Determining Steady State Thermal Transmittance of Fenestration Systems
- ASTM E1748 Test Method for Evaluating the Engagement Between Windows and Insect Screens as an Integral System
- ASTM E1886 Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials
- ASTM E1996 Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes
- ASTM E2068 Test Method for Determination of Operating Force of Sliding Windows and Doors
- ASTM E2268 Test Method for Water Penetration of Exterior Windows, Skylights, and Doors by Rapid Pulsed Air Pressure Difference
- ASTM E2353 Test Methods for Performance of Glazing in Permanent Railing Systems, Guards, and Balustrades
- ASTM E2357 Standard Test Method for Determining Air Leakage Rate of Air Barrier Assemblies
- ASTM F588 Test Methods for Measuring the Forced Entry Resistance of Window Assemblies, Excluding Glazing Impact
- ASTM F842 Test Methods for Measuring the Forced Entry Resistance of Sliding Door Assemblies, Excluding Glazing Impact
- ASTM F2006 Standard Safety Specification for Window Fall Prevention Devices for Non-Emergency Escape (Egress) and Rescue (Ingress) Windows
- ASTM F2090 Standard Specification for Window Fall Prevention Devices with Emergency Escape (Egress) Release Mechanisms
- CRF, Title 10, Chapter II, Subchapter D, Park 431, Subpart R, Appendix A Walk-in Coolers and Walk-in Freezers
- CSA A440-S1 American Fenestration Standard/Specification for Windows, Doors, and Skylights
- FM Global 1-52 Field Verification of Roof Window Uplift Resistance
- ICC 500 Standard for Design and Construction of Storm Shelters, Test Methods for Impact and Pressure Testing, Chapter 8 only
- ANSI/NFRC 100 Procedure for Determining Fenestration Product U-factors
- NFRC 102 Procedure for Measuring the Steady-State Thermal Transmittance of Fenestration Systems
- ANSI/NFRC 200 Determining Fenestration Product Solar Heat Gain Coefficient
- ANSI/NFRC 500 Fenestration Product Condensation Resistance
- NHTSA/FMVSS 49 CFR 571.217 Standard No. 217 Bus Emergency Exits and Window Retention and Release
- TAS 100A Test Procedure for Wind and Wind Driven Rain Resistance and/or Increased Windspeed Resistance of Soffit Ventilation Strip and Continuous or Intermittent Ventilation System Installed at the Ridge Area
- TAS 201 Impact Test Procedures
- TAS 202 Criteria for Testing Impact & Nonimpact Resistant Building Envelope Components Using Uniform Static Air Pressure
- TAS 203 Criteria for Testing Products Subject to Cyclic Wind Pressure Loading
- WDMA 1.S.11 Industrial Standard for Analytical Method for Design Pressure Rating of Fenestration Products
-
- TAS 100(A) Test Procedure for Wind and Wind Driven Rain Resistance and/or Increased Windspeed Resistance of Soffit Ventilation Strip and Continuous or Intermittent Ventilation System Installed at the Ridge Area
- TAS 201 Impact Test Procedures
- TAS 202 Criteria for Testing Impact & AMp, Nonimpact Resistant Building Envelope Components Using Uniform Static Air Pressure
- TAS 203 Criteria for Testing Products Subject to Cyclic Wind Pressure Loading
- ASTM E1886 Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials
- ASTM E1996 Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes
- ASTM E2068 Test Method for Determination of Operating Force of Sliding Windows and Doors
- Simulation Laboratory
- Testing Laboratory
- Independent Approved Calculation Entity
- NFRC 102 Procedure for measuring the steady-state thermal transmittance of fenestration systems
- NFRC 400 Air Test
- NFRC 100/200/500 NFRC Simulation Window 6/7 & THERM 6/7
- NFRC 100/200/500 NFRC Simulation CMA
- NFRC 100/200/500 NFRC Simulation ACE
- AAMA 501 Methods of Test for Exterior Walls
- AAMA 501.9 Surface Temperature Assessment for Condensation Evaluation of Exterior Wall Systems
- AAMA 506 Voluntary Specification for Impact and Cycle Testing of Fenestration Products
- AAMA 508 Voluntary Specification for Pressure Equalized Rain Screen Wall Cladding Systems
- AAMA 509 Voluntary Test and Classification Method for Drained and Back Ventilated Rain Screen Wall Cladding Systems
- AAMA 511 Voluntary Guideline for Forensic Water Penetration Testing of Fenestration Products
- AAMA 514 Test Method for Static Loading and Impact on Exterior Shading Devices
- AAMA 515 Voluntary Procedure for Determination of Fenestration Surface Temperatures by THERM Finite Element Modeling
- AAMA 1302.5 Voluntary Specification for Forced Entry Resistant Aluminum Prime Windows
- AAMA 1303.5 Voluntary Specification for Forced Entry Resistant
- ASTM E2128 Standard Guide for Evaluating Water Leakage of Building Walls
- ASTM E2358 Standard Specification for Performance of Glazing in Permanent Railing Systems, Guards, and Balustrades
- ANSI/NFRC 400 Procedure for Determining Fenestration Product Air Leakage
- ANSI/NFRC 507 Standard Practice for Determining the Thermal Performance Characteristics of Fenestration Systems in Commercial Buildings
- NYC DOHMH Window Guards
CORPORATE OFFICE & LABORATORY
Mosinee, WI
Phone: 715-693-TEST (8378)
Fax: 715-693-0689
Quast Consulting and Testing, Inc
1055 Indianhead Drive
Mosinee, WI 54455
FIELD OFFICE
Chicago, IL
Matt Wendland
Phone: 715-302-0098
CORPORATE OFFICE & LABORATORY
Mosinee, WI
Phone: 715-693-TEST (8378)
Fax: 715-693-0689
Quast Consulting and Testing, Inc
1055 Indianhead Drive
Mosinee, WI 54455
FIELD OFFICE
Chicago, IL
Matt Wendland
Phone: 715-302-0098